Learn about Coriolis Measuring Principles.
Hover mouse over icon for application notes.
Differential Pressure Capabilities
| Technology |
Model/
Series |
Gas Flow |
Liquid Flow |
Steam Flow |
Line Size |
Temperature |
Pressure |
Viscosity |
Accuracy |
Considerations |
| DP Meters |
ALDP |
 |
 |
 |
 |
 |
 |
 |
 |

Must include DP transmitter |
Differential Pressure Flow Meters
| Differential Pressure Family |
| Technology |
Model |
Diameters |
Flow Rate |
Accuracy |
Pressure |
Temperature |
Materials |
Special Features |

Cone |
ACONE |
½"~120"
(15~3000mm) |
Based on Re > 8000 For Gases, Liquid and Steam |
Liquid: ± 0.5% of reading,
Gas & Steam: ± 1.0% of reading |
61,000 psig
(420 Mpa) |
320~1500°F
(-196~850 °C) |
SS #304L/SS #316L, CPVC ,PTFE, Brass, A106B A335-P11, A335-P22, Dual - Phase Steel, Inconel 625, Hastelloy C276 |
Reduced stright-pipe requirements; only 3 Φ upstream and 1 Φ downstream |

DP 1051 |
ALDP-1051 |
ulimited |
Depends (ACONE, ALDPWG or ALDPBL) |
Accuracy GRADE 0.075, 0.2, 0.5 |
DP: 0~0.16 kPa to 0~10 Mpa,
RP max 0~40 Mpa, min 0~0.16 Kpa
AP max 0~25 Mpa, min 0~20 Kpa |
-40~212 °F
(-40 ~ 100 °C) |
SS #316, Tantalum and other exotic materials |
HART protocol, Profibus, or FOUNDATION fieldbus |

DP-3051 |
ALDP-3051 |
ulimited |
Depends (ACONE, ALDPWG or ALDPBL) |
Accuracy GRADE 0.075, 0.2, 0.5 |
DP: 0~0.16 kPa to 0~10 Mpa,
RP max 0~40 Mpa, min 0~0.16 Kpa
AP max 0~25 Mpa, min 0~20 Kpa |
-40~212 °F
(-40 ~ 100 °C) |
SS #316, Tantalum and other exotic materials |
HART protocol, Profibus, or FOUNDATION fieldbus |

Balance |
ALDPBL |
½"~12"
(15~400mm) |
Re < 500 |
(calibrated): 0.3% or 0.5%;
(un-calibrated): 0.5% to 1% |
61,000 psig
(420 Mpa) |
320~1500°F
(-196~850 °C) |
304L/SS, 306L, CPVC ,PTFE, Brass, A106B A335-P11, A335-P22, Dual - Phase Steel, Inconel 625, Hastelloy C276 |
No straight- run required, 50% lower DP loss vs. orifice, less noise and vibration |

Wedge |
ALDPWG |
½” to 40”
(15~DN1000 mm) |
Re < 500 |
(calibrated): 1% or 0.5%;
(un-calibrated): 3% |
6000 PSIG
(42.0MPa) |
750 °F
(400 °C) |
Body: Cast lron, SS, high Talloy, Wedge:SS, Monel, Hastelloy C,high T alloy. |
Bi-directional, good for high viscosity fluids; tar, sand,concrete, mud, etc. |