The SMC ALMAGHP is an electromagnetic flowmeter designed to measure the flow rates of conductive liquids in applications with high operating pressures. The robust design of the ALMAGHP allows it to be used in applications with pressures in excess of 6000 psig 42 Mpa). Line sizes ranging from ¼" to 64" (6 to 1600 mm) can be accommodated by the ALMAGHP, with available process connections including ANSI, DIN, and JIS-type flanges. A wide selection of options are also available for the display/converter module including integral or remote mounting, 110-220 VAC or 17-26 VDC power, and HART, RS485 & Profibus communications This magmeter's unique ability to withstand high pressures, combined with its wide array of available features, makes it an ideal choice for many applications & industries. The ALMAGHP has been successfully used in high pressure fluid injection, steel, chemical and mining and a variety of industrial applications
- Various liner/electrode material combinations can be selected in order to achieve chemical compatibility with different fluids.
- Capable of measuring fluid velocities of up to 40 feet/second (12 m/s), with a high turndown ratio.
- Flange-type process connections are standard; ANSI, DIN, JIS styles available
- Suitable for high pressure operation in excess of 6000 psig.
- IP68 protection class for submersible operation
- Available FEP liner suitable for vacuum conditions.
- High accuracy - ±0.5% of reading (standard) or ±0.2% of range
- Diagnostic features alert the user to empty pipe or reverse flow conditions.
| Sizes |
Standard ¼" ~ 64" (DN6 ~ DN1600)
High pressure 1" ~ 8" (DN25 ~ DN200) |
| Process Pressure |
87-6100 psig (0.6~42 Mpa) |
| Process Temperature |
14 ~ 140 °F (-10 ~ 60 °C) –Polyurethane
-4 ~ 158 °F (-20 ~ 70 °C) – Neoprene
-40 ~ 356 °F (-40 ~ 180 °C) – FEP
-40 ~ 356 °F (-40 ~ 180 °C) - PTFE |
| Measuring Range |
0-40 feet/sec (0 - 12 m/s max) |
| Materials of Construction |
Measuring Tube - Stainless Steel 304
Coil housing – Carbon steel (Coated)
Flanges - Carbon steel (Coated)
Electrical Enclosure – Aluminum (coated) |
| Liner |
Polyurethane - 1"-24" (25-600 mm)
Neoprene - 2"-64" (50-1600 mm)
FEP - ¼"-12" (6-300 mm)
PTFE - 1"-32" (25-800 mm) |
|
|
| Electrode & Grounding |
Stainless Steel 316L
Hastelloy B
Hastelloy C
Titanium
Tantalum
Tungsten Carbide |
| Cable Entry |
2 X PG11 |
| Ambient Temperature |
-15~140 °F (-25~60 °C) |
| Process Connections |
Flange |
| Grounding Resistance |
Must be less then 10 Ω |
| Accuracy |
±0.5% of reading
±0.2% of FS |
| Protection |
IP 65, Ior
IP 68 (Submersible) |
| Conductivity |
must be ≥ 5 µS/cm |
|