The SMC ALMAGIS is an insertion electromagnetic flowmeter designed to measure the fluid velocity of conductive liquids in applications where hot-tap or insertion installations are preferred. This insertion mag meter is available in four standard lengths and may be installed in any pipeline with internal diameters ranging from 300 mm (12") to3000 mm (120")and in permanent locations where cost or space limitations preclude the use of conventional in-line style meters. Pipe connections come in hot-tapped, DIN and NPT threads. The ALMAGIS is designed for use conductive fluids including water, raw sewage, and wastewater, clarified water, RAS, and WAS, primary sludge and cooling tower water, as long as adequate lengths of straight pipe are available where the sensor is installed.
- Applicable sizes: 6"~120" ( 150~3000mm)
- Operating pressure: = 230 psig (1.6MPa)
- Velocity range of 3-33 fps (1~10m/s)
- Accuracy: ±2.5%
- Hot-tap sensor can be installed and retracted from process piping
- Conductivity of measured medium: =50µs/cm
- Electrode materials: 316L, hastelloy, Ti, etc
- The max. distance between sensor and converter: =50m (165 feet)
- NIST traceable calibration certificate
| Size |
6"~120" (150-3000mm) |
| Measuring Range |
3-33 fps (1 - 10 m/s); bi-directional |
| Temperature |
160 °F (70 °C) max. |
| Pressure |
230 psig (1.6Mpa) max. |
| Wetted part |
Stainless Steel #304 |
| Protection |
IP 67 |
| Materials (std) |
Transmitter housing : Aluminium
Probe : SS #304
Detector housing : SS #316L |
| Conductivity |
must be = 50 µS/cm |
|
|
| Cable Entry |
2 X PG11 |
| Ambient Temperature |
-13 to 140 °F (-25 to 60 °C) |
| Connection |
Weld, Flange, thread and ball vavle |
| Coil Resistance |
50~70 O (std) |
| Accuracy |
±2.5% of reading |
| Power requirements |
24 VDC, 110-220 VAC |
| Outputs |
Analog : 4-20mA, Pulse
Digital : RS232/485, HART, Modbus-RTU, Profibus-DP |
|