| Measuring Principle |
Doppler frequency shift |
| Transducers |
(Std) 1" - 120" [25 - 3050 mm]
(Opt) ¼" - 1" inch [6 - 25 mm] |
| Temperatures |
(Std) -40 to 180 °F [-40 to 82 °C]
(Opt) -40 to 300 °F [-40 to 150°C] |
| Fluid Velocity |
Clamp on, 1 - 20 FPS [0.3 - 6.08 MPS]
Insertion: 0.5 - 20 FPS [0.15 - 6.08 MPS] |
| Minimum Particulates |
25 ppm of 30 micron size |
| Accuracy |
±2% Full Scale |
| Repeatability |
±0.4% of Full Scale |
| Resolution |
0.4% of Full Scale |
| Response Time |
5-50 seconds, user configured, to 90% of value |
| Display |
2 line x 20 character alphanumeric LCD (backlit)
6 digits - flow rate, 6 digits - total flow |
| Indicators |
Power, Signal Strength, Flow Analyzer, Fault, Over-range, Read, Low Battery, Charge |
|
|
| Engineering Units |
FPS, GPM, MGD [MPS, LPM, M3/hr] |
| Ambient temperature |
-22 to 160 °F [-30 to 70 °C] |
| Protection - Converter |
NEMA 4X, [IP-65] ABS |
| Protection - Transducers |
IP 68 |
| Max Cable Length |
6m, flexible armored conduit, Up to 100m |
| Power Consumption |
Less than 12VA |
| Power Supply |
Wall Mount: 115/230 VAC 50/60 Hz ±10% and 12VDC
Portable: Internal Lead acid Gel Cell battery provides up to 8 hrs of continuous operation |
| Outputs |
Wall Mount: 4-20 mA, pulse, RS232, RS485
Portable: 4-20 mA, 600 Ω max., isolated |
| Software |
Windows-based with utility reports, data logging software various reports, curves and analysis |
| Data Logger |
4.0M byte data logger up to 200,000 records |
| Approvals |
CE |
|