Gas Flow Liquid Flow Steam Flow Line Size Temperature Pressure Viscosity Accuracy Considerations
Variable Area ALVAMT 0.03 ~ 4K ACMH<br />0.01 ~ 2354 ACFM 0.01 ~  3,333 LPM<br />0.003~881 GPM Cannot Measure 6 ~ 200 mm<br />¼" ~ 8" -80 ~ +200 °C<br />-112 ~ +392 °F 40 bar<br />580 PSI < 300 CP ± 1% of Reading Liquids must be clean
Liquids must be clean

 

Variable Area Flow Meters

ALVA Family
Technology Model Line Sizes Flow Rate Viscosity Accuracy Pressures Temperature Materials Mounting Orientations Outputs
ALVAMT
Metal Tube
ALVAMT ½"-8"
(8 - 400mm)
0.01-660 GPM
(0.05 - 2,500 LPM)
1~300 cP ±1.5% (Std), ±2.5% w/ PTFE materials 930 psig (64 barg) 575 °F (300 °C) max 304SS (Std); 316SS, PTFE, or Tantalum (Opt) Horizontal or vertical Analog 4-20 mA, 0-5 VDC, HART, swtch & open collector
Glass Tube
Glass Tube
Not Available From SMC ¼" - 3"
(6 - 80mm)
0.05 to 264 GPM (0.005 to 1000 LPM) < 50 cP recommended ±0.50% ~ ±5.0 of reading depending on make & model <100 psig (7 barg) Up to 350 °F (180 °C) max. depending on make & model Borosilicate, acrylic, or polycarbonate tube, Stainless Steel float, depends on make & model Vertical only Switch & open collector

 