Flow range: up to 8800 GPM (2000 m3/hr) |
|
Accuracy: ±0.1% |
Line size: ¼”~16” (8~400mm), ANSI or DIN type flange |
|
Repeatability: ±0.01% |
| |
connections |
|
Pulse Output: (24VDC ±5%, VH≥20V), VL<1V and output |
Operating pressure: max. 930 psig (64 bar) |
|
|
load <200Ω) |
Process temperature: -22~+480 °F (-30~+250 ℃) |
|
Current Output: 4~20mA, (two wire system w/ 0~ 600Ω |
| Body Material: Stainless Steel 304 and Carbon Steel |
|
|
output load) |
Display: rate, total, low flow cut-off, battery consumption, |
|
Digital output: RS485/RS232 communication with Modbus |
Viscosity: 0~20,000 cP |
|
|
RTU (powered by 24VDC ± 5% and <60mA) |
| Working Humidity: <90%@ 75 °F (25 ℃) |
|
User parameters: K-factors, signal selction points, |
Housing protecton: NEMA 4 (IP 65), Exd IIBT 4 |
|
|
temperature and pressure compensation, set |
Working Temperature: -40~+176 °F (-40~+80 ℃) |
|
|
pulse output, etc |
communication baud rates: User selectable (1200 ,2400, |
|
|
|
| |
4800 or 9600) |
|
|
|
|
|
. |
|