Conductivity of Cadium Nitrate
   
 Forum | Application | Technology | Products | Calibration | Currency | Conversion 
 Home | Shopping Cart | Logout
Fluid Conductivity
 
Flowmeter > Magnetic > Conductivity > Cadium Nitrate
Conductivity of Cadium Nitrate
Green numbers indicate high conductivity fluids suitable for magnetic flowmeters. Orange numbers indicate low conductivity and may not lead to successful applications. Red numbers warn that conductivities are too low to use magnetic flowmeters.

Concentration Temperature Conductivity
(weight %) (°C) (°F) (µS/cm) (µS/in)
1 18 64.4 6940 17600
5 18 64.4 28900 73400
10 18 64.4 51300 130300
20 18 64.4 82700 210100
30 18 64.4 95600 242800
40 18 64.4 90300 229400
48 18 64.4 75500 191800